Pompa Suntik KL-6061N
Pompa Suntik KL-6061N
Spesifikasi
| Ukuran Suntik | 5, 10, 20, 30, 50/60 ml |
| Suntik sing ditrapake | Kompatibel karo jarum suntik standar apa wae |
| Laju Aliran | Suntik 5 ml: 0,1-100 ml/jam Suntik 10 ml: 0,1-300 ml/jam Suntik 20 ml: 0,1-600 ml/jam Suntik 30 ml: 0,1-800 ml/jam Suntik 50/60 ml: 0,1-1500 ml/jam 0,1-99,99 mL/jam, kanthi tambahan 0,01 ml/jam 100-999,9 ml/jam kanthi tambahan 0,1 ml/jam 1000-1500 ml/jam kanthi tambahan 1 ml/jam |
| Akurasi Laju Aliran | ±2% |
| VTBI | 0.10mL~99999.99mL(Minimal kanthi tambahan 0,01 ml/jam) |
| Akurasi | ±2% |
| Wektu | 00:00:01~99:59:59(h:m:s)(Minimal ing tambahan 1 detik) |
| Laju Aliran (Bobot awak) | 0.01~9999.99ml/jam ;(kanthi tambahan 0,01 ml) unit:ng/kg/menit、ng/kg/jam、ug/kg/menit、ug/kg/jam、mg/kg/menit、mg/kg/jam、IU / kg / min、IU/kg/jam、EU/kg/menit、EU/kg/jam |
| Tingkat Bolus | Suntik 5 ml: 50mL/jam-100.0 mL/jam Suntik 10 ml: 50mL/jam-300.0 mL/jam Suntik 20 ml: 50mL/jam-600.0 mL/jam Suntik 30 ml: 50mL/jam-800.0 mL/jam Suntik 50/60 ml: 50mL/jam-1500.0 mL/jam 50-99,99 mL/jam, kanthi tambahan 0,01 ml/jam 100-999,9 ml/jam kanthi tambahan 0,1 ml/jam 1000-1500 ml/jam kanthi tambahan 1 ml/jam Akurasi: ±2% |
| Volume Bolus | Suntik 5 ml: 0.1mL-5.0 mL Suntik 10 ml: 0,1mL-10,0 mL Suntik 20 ml: 0,1mL-20,0 mL Suntik 30 ml: 0,1mL-30,0 mL Suntik 50/60 ml: 0.1mL-50.0 /60.0mL Akurasi:±2% utawa±0.2mL |
| Bolus, Pembersihan | Suntik5mL:50mL/jam-100,0 mL/jam Suntik10mL:50mL/jam-300,0 mL/jam Suntik20mL:50 ml/jam-600,0 mL/jam Suntik30mL:50 ml/jam-800,0 mL/jam Suntik50mL:50 ml/jam-1500,0 mL/jam (Minimal ing(tambahan 1mL/jam) Akurasi:±2% |
| Sensitivitas Oklusi | 20kPa-130kPa, bisa diatur (ing10 kPatambahan) Akurasi: ±15 kPa or±15% |
| Tarif KVO | 1). Fungsi Nyala/Mati KVO Otomatis 2).KVO otomatis dipateni : KVO Rate :0.1~10,0 mL/jambisa diatur,(Minimalkanthi tambahan 0,1 mL/jam). Nalika laju aliran > laju KVO , iku lumaku ing laju KVO. Nalika laju aliran 3) KVO otomatis diuripake: nyetel laju aliran kanthi otomatis. Nalika laju aliran <10mL/jam, laju KVO = 1mL/jam Nalika laju aliran >10 mL/jam, KVO=3 mL/jam. Akurasi:±2% |
| Fungsi dhasar | Pemantauan tekanan dinamis, Anti-Bolus, Kunci Kunci, Siaga, Memori historis, Perpustakaan obat. |
| Alarm | Oklusi, syringe mudhun, lawang mbukak, cedhak pungkasan, program rampung, baterei lemah, baterei rampung, kerusakan motor, kerusakan sistem, alarm siaga, kesalahan instalasi syringe |
| Mode Infus | Mode laju, Mode wektu, Bobot awak, Mode urutan, Mode dosis, Mode ramp munggah/mudhun, Mode mikro-infus |
| Fitur Tambahan | Pamriksan Mandiri, Memori Sistem, Nirkabel (opsional), Kaskade, Prompt Baterai Ilang, Prompt Daya AC Mati. |
| Deteksi Udara-in-line | Detektor ultrasonik |
| Catu Daya, AC | AC100V~240V 50/60Hz,35 VA |
| Baterei | 14.4 V, 2200mAh, Lithium, bisa diisi ulang |
| Bobot Baterei | 210g |
| Daya Tahan Baterai | 10 jam kanthi 5 ml/jam |
| Suhu Kerja | 5℃~40℃ |
| Kelembapan Relatif | 15%~80% |
| Tekanan Atmosfer | 86KPa~106KPa |
| Ukuran | 290×84×175mm |
| Bobot | <2,5 kg |
| Klasifikasi Keamanan | Kelas ⅠI, tipe CF. IPX3 |
Pitakonan sing Sering Ditakoni:
Q:pira MOQ kanggo model iki?
A: 1 unit.
P: Apa OEM bisa ditampa? Lan apa MOQ kanggo OEM?
A: Ya, Kita bisa nindakake OEM adhedhasar 30 unit.
P: Apa sampeyan sing nggawe produk iki?
A: Inggih, wiwit taun 1994
P: Apa sampeyan duwe sertifikat CE lan ISO?
A: Ya. Kabeh produk kita wis disertifikasi CE lan ISO
P: Apa garansine?
A: Kita menehi garansi rong taun.
P: Apa model iki bisa digunakake karo stasiun Docking?
A: Inggih